Evidence
43 project figures, each with its type, source and the date I last checked it.
Show
Showing all rows.
- measured
- counted or tested in the work shown
- cited
- taken from a document
- target
- a design target
- ongoing
- in progress
- noted
- a recorded detail from a test or report
Single-cell Flex v2
Open Single-cell Flex v2Tissue details and study results are not published.
About half
Share of the Cincinnati Children's placement spent on Flex v2 work
Note
Owner's estimate; no time log.
owner statement 2026-10-21 checked 21 Oct 2026
cited
Protocol, samples, custom probes and analysis
Prepared the protocol, samples and custom probes, and ran the data analysis for Flex v2
Note
Owner statement for the Flex v2 work at Cincinnati Children's Research Foundation.
owner statement 2026-10-22 checked 22 Oct 2026
cited
88
Samples run through the full Flex v2 protocol
owner statement 2026-10-22 checked 22 Oct 2026
cited
Cell Ranger
Software I used to analyze the Flex v2 sequencing data
owner statement 2026-10-22 checked 22 Oct 2026
cited
Illumina
Sequencing platform for the Flex v2 mouse study
owner statement 2026-10-22 checked 22 Oct 2026
cited
Mouse study
Study context for the Flex v2 samples
owner statement 2026-10-22 checked 22 Oct 2026
cited
Mass-spec macro
Open Mass-spec macro80%
Analysis-time reduction from the Excel/VBA mass-spec macro
Note
Historical résumé claim; no baseline timing or measurement method is on file.
Résumé, Research Student II and Mass-Spectrometry Data Automation checked 20 Oct 2026
cited
Mainly human samples
Samples processed with the mass-spec macro
Note
The macro also supported samples from the same mouse study as the Flex v2 work. The 70+ animal-study sample figure belongs to the placement overall, not the macro.
owner statement 2026-10-22 checked 22 Oct 2026
cited
LungScope
Open LungScopeOne SPRSound snapshot, from the validation report in the résumé. Counts only; no accuracy claim.
6,567
Source recordings checked in the SPRSound snapshot
measured
24,578
Event annotations checked
measured
6,566
Canonical recordings kept after resolving one conflicting duplicate
Note
Source aliases and annotations are kept.
measured
5,881
Recordings eligible for supervised training
measured
854
Known subjects among the eligible recordings
measured
598
Train split, counted in subjects
Note
Split by subject.
measured
128
Validation split, counted in subjects
Note
Split by subject.
measured
128
Test split, counted in subjects
Note
Split by subject; 598 + 128 + 128 = 854.
measured
0
Subjects or identical PCM audio shared between splits
Note
Source: v0.11.3 validation report.
measured
ECG board
Open ECG board9600 baud
Serial speed between Arduino and Processing
cited
450
Beat-detection threshold in the Processing monitor
Note
A raw ADC count hard-coded in the source: a fixed threshold with no adaptive detection.
cited
A1
Analog input used on the Ninetales board
cited
about 100 Hz
Nominal sampling rate from a 10 ms loop delay
Note
Nominal: the 10 ms delay plus conversion and serial time.
Arduino source (delay(10)), Résumé
target
Pediatric arch support
Open Pediatric arch support3 of 3
Static load tests, insert unaffected (30 lb for 1 minute)
Note
Small bench test on one prototype. It gives no statistical or clinical result.
measured
2 of 3
Impact tests, insert unaffected (30 lb dropped from 1 ft)
Note
Small bench test on one prototype.
measured
V2 (beta)
Prototype iteration we built
Note
The final report calls V2 a functional alpha; the résumé calls it a beta. V1 used cardboard and foam.
Final report, Prototype journey, Résumé
measured
5 to 7 years
Target users: children aged 5 to 7 with symptomatic pes planus
Note
The intended population. No pediatric clinical study was run.
Final report, problem statement, Résumé, Pediatric Arch Support
cited
0 built
V3 built
Note
V3 (custom-molded hybrid inserts, reinforced pouch) was planned and handed to a future team. It was not built.
Final report, Technical Memo, Résumé
ongoing
10%
Room for up to 10% volumetric foot growth
Note
Design target. The report lists tensile-strain testing and compression mapping as planned methods and gives no result.
target
150 N
Target ground-reaction load
Note
Design target. Our static test used a 30 lb load for 1 minute, which does not verify 150 N.
target
< 8 mm
Midfoot thickness under 8 mm
Note
Design target. The report lists caliper measurement as the planned method and gives no measured thickness.
target
1 of 3
Third impact test: insert slightly damaged, gel partly contained, slight leakage
Note
The report says slight damage and slight leakage, with no rupture. The pass criterion was an insert that stays fully intact. The result points at gel containment.
noted
JobHub
Open JobHub8
API providers configured in the collector
Note
Count of provider definitions in one source file; the collector rule allows official public APIs only.
measured
28
Database tables in the accounts database
Note
Count of CREATE TABLE statements in schema.sql. The job-data database adds 19 more.
measured
Research
Open Research27
Participants with obesity and no associated metabolic disorder (paper)
Note
Reported in the paper; I contributed to sample collection and processing.
cited
15
cited
184
Proteins measured on an Olink panel (paper)
Note
Panel size as reported by the paper.
cited
24
Differentially expressed proteins (paper)
Note
The paper reports 13 lower and 11 higher proteins in the obesity group.
cited
711
Serum metabolites kept after quality control (preprint)
Note
Preprint, not peer-reviewed. Reported differences were not corrected for multiple testing and remain exploratory.
cited
50+
Endocrine research samples processed at iTRI
Note
Source: résumé.
Résumé, Clinical Research Assistant
cited
4
Incoming team members I trained
Note
Source: résumé.
Résumé, Clinical Research Assistant
cited
Other figures from my résumé
Open Aboutabout 60
Residents in my Resident Advisor community
Note
Approximate figure from earlier résumé records.
Résumé, Resident Advisor
cited
over 100
Cumulative attendance at events I planned
Note
Figure from earlier résumé records.
Résumé, Resident Advisor
cited
2 (2022, 2023)
FIRST Global Challenge world events attended for Qatar
Note
Geneva, Switzerland, 2022; Singapore, 2023. Documented in résumé.
Résumé, FIRST Robotics
cited
Current co-op
Open AboutAug 2026
Live Well co-op start
Note
Ongoing; no end date set.
ongoing