43 project figures, each with its type, source and the date I last checked it.

measured
counted or tested in the work shown
cited
taken from a document
target
a design target
ongoing
in progress
noted
a recorded detail from a test or report

Single-cell Flex v2

Open Single-cell Flex v2

Tissue details and study results are not published.

  • About half

    Share of the Cincinnati Children's placement spent on Flex v2 work

    Note

    Owner's estimate; no time log.

    owner statement 2026-10-21 checked 21 Oct 2026

    cited

  • Protocol, samples, custom probes and analysis

    Prepared the protocol, samples and custom probes, and ran the data analysis for Flex v2

    Note

    Owner statement for the Flex v2 work at Cincinnati Children's Research Foundation.

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

  • 88

    Samples run through the full Flex v2 protocol

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

  • Cell Ranger

    Software I used to analyze the Flex v2 sequencing data

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

  • Illumina

    Sequencing platform for the Flex v2 mouse study

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

  • Mouse study

    Study context for the Flex v2 samples

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

Mass-spec macro

Open Mass-spec macro

  • 80%

    Analysis-time reduction from the Excel/VBA mass-spec macro

    Note

    Historical résumé claim; no baseline timing or measurement method is on file.

    Résumé, Research Student II and Mass-Spectrometry Data Automation checked 20 Oct 2026

    cited

  • Mainly human samples

    Samples processed with the mass-spec macro

    Note

    The macro also supported samples from the same mouse study as the Flex v2 work. The 70+ animal-study sample figure belongs to the placement overall, not the macro.

    owner statement 2026-10-22 checked 22 Oct 2026

    cited

LungScope

Open LungScope

Résumé, LungScope section (v0.11.3 validation report), Résumé, 3 pageschecked 20 Oct 2026

One SPRSound snapshot, from the validation report in the résumé. Counts only; no accuracy claim.

  • 6,567

    Source recordings checked in the SPRSound snapshot

    measured

  • 24,578

    Event annotations checked

    measured

  • 6,566

    Canonical recordings kept after resolving one conflicting duplicate

    Note

    Source aliases and annotations are kept.

    measured

  • 5,881

    Recordings eligible for supervised training

    measured

  • 854

    Known subjects among the eligible recordings

    measured

  • 598

    Train split, counted in subjects

    Note

    Split by subject.

    measured

  • 128

    Validation split, counted in subjects

    Note

    Split by subject.

    measured

  • 128

    Test split, counted in subjects

    Note

    Split by subject; 598 + 128 + 128 = 854.

    measured

  • 0

    Subjects or identical PCM audio shared between splits

    Note

    Source: v0.11.3 validation report.

    measured

ECG board

Open ECG board

checked 20 Oct 2026

Pediatric arch support

Open Pediatric arch support

checked 20 Oct 2026

  • 3 of 3

    Static load tests, insert unaffected (30 lb for 1 minute)

    Note

    Small bench test on one prototype. It gives no statistical or clinical result.

    Final report, Verification Testing / Results

    measured

  • 2 of 3

    Impact tests, insert unaffected (30 lb dropped from 1 ft)

    Note

    Small bench test on one prototype.

    Final report, Verification Testing / Results

    measured

  • V2 (beta)

    Prototype iteration we built

    Note

    The final report calls V2 a functional alpha; the résumé calls it a beta. V1 used cardboard and foam.

    Final report, Prototype journey, Résumé

    measured

  • 5 to 7 years

    Target users: children aged 5 to 7 with symptomatic pes planus

    Note

    The intended population. No pediatric clinical study was run.

    Final report, problem statement, Résumé, Pediatric Arch Support

    cited

  • 0 built

    V3 built

    Note

    V3 (custom-molded hybrid inserts, reinforced pouch) was planned and handed to a future team. It was not built.

    Final report, Technical Memo, Résumé

    ongoing

  • 10%

    Room for up to 10% volumetric foot growth

    Note

    Design target. The report lists tensile-strain testing and compression mapping as planned methods and gives no result.

    Final report, sections 1 and requirements table

    target

  • 150 N

    Target ground-reaction load

    Note

    Design target. Our static test used a 30 lb load for 1 minute, which does not verify 150 N.

    Final report, requirements table

    target

  • < 8 mm

    Midfoot thickness under 8 mm

    Note

    Design target. The report lists caliper measurement as the planned method and gives no measured thickness.

    Final report, requirements table

    target

  • 1 of 3

    Third impact test: insert slightly damaged, gel partly contained, slight leakage

    Note

    The report says slight damage and slight leakage, with no rupture. The pass criterion was an insert that stays fully intact. The result points at gel containment.

    Final report, Verification Testing / Results, Résumé

    noted

JobHub

Open JobHub

JobHub repository (private), branch feat/landing-feature-demos @ c65956dchecked 21 Oct 2026

  • 8

    API providers configured in the collector

    Note

    Count of provider definitions in one source file; the collector rule allows official public APIs only.

    measured

  • 28

    Database tables in the accounts database

    Note

    Count of CREATE TABLE statements in schema.sql. The job-data database adds 19 more.

    measured

Research

Open Research

checked 20 Oct 2026

  • 27

    Participants with obesity and no associated metabolic disorder (paper)

    Note

    Reported in the paper; I contributed to sample collection and processing.

    IJMS paper, Abstract

    cited

  • 15

    Lean healthy controls (paper)

    Note

    Reported by the paper.

    IJMS paper, Abstract

    cited

  • 184

    Proteins measured on an Olink panel (paper)

    Note

    Panel size as reported by the paper.

    IJMS paper, Abstract

    cited

  • 24

    Differentially expressed proteins (paper)

    Note

    The paper reports 13 lower and 11 higher proteins in the obesity group.

    IJMS paper, Abstract

    cited

  • 711

    Serum metabolites kept after quality control (preprint)

    Note

    Preprint, not peer-reviewed. Reported differences were not corrected for multiple testing and remain exploratory.

    Preprint, Methods

    cited

  • 50+

    Endocrine research samples processed at iTRI

    Note

    Source: résumé.

    Résumé, Clinical Research Assistant

    cited

  • 4

    Incoming team members I trained

    Note

    Source: résumé.

    Résumé, Clinical Research Assistant

    cited

Other figures from my résumé

Open About

checked 20 Oct 2026

  • about 60

    Residents in my Resident Advisor community

    Note

    Approximate figure from earlier résumé records.

    Résumé, Resident Advisor

    cited

  • over 100

    Cumulative attendance at events I planned

    Note

    Figure from earlier résumé records.

    Résumé, Resident Advisor

    cited

  • 2 (2022, 2023)

    FIRST Global Challenge world events attended for Qatar

    Note

    Geneva, Switzerland, 2022; Singapore, 2023. Documented in résumé.

    Résumé, FIRST Robotics

    cited

Current co-op

Open About

Résumé, Professional Experiencechecked 20 Oct 2026

  • Aug 2026

    Live Well co-op start

    Note

    Ongoing; no end date set.

    ongoing